High Performance Polymer Panels
EGR Polymer Panel Technical Data Sheet - Lustrolite 100®
General Properties
Properties Text Method Lustrolite
Thickness   5/32" (4mm)
Specific gravity ASTM D-792 1.2
Water absorption ASTM D-570 0.15%
Gloss** AS/NZS 1580.602 >90%
Tensile strength ASTM D-638 60MPa
Elongation at Yield ASTM D-638 6%
Tensile modulus ASTM D-638 2,410 MPa
Flexural strength ASTM D-790 96 MPa
Flexural modulus ASTM D-790 2,410 MPa
Izod impact strength, Milled Notch ASTM D-256 950J/m
Pencil Hardness** ASTM D-3363 >6H
Erichsen Hardness** ISO 4586-2 (DIN EN 438-2) ≥ 0.5N
Abrasion ASTM D-1044 < 10 % Gloss
HDT 264 Psi, 1.82MPa ASTM D-648 269°F (132°C)
CTE, -30°C to 30°C ASTM D-696 0.65mm/36”/18°F
(0.7mm/1,000mn/10°C)
Vicat softening point   304°F (151°C)
Continuous service temperature   212°F (100°C)
Max temperature, short term   302°F (150°C)

* Internally tested by EGR

General Resistance

Lustrolite 100 is chemically resistant to the following substances:

  • Kerosene
  • Bleach
  • Mineral Spirits
  • 10% Citric Acid
  • Lemon Juice
  • Vinegar
  • Coffee
  • Liquid Soap
  • Glass Cleaner

Lustrolite should not be exposed the following substances:

  • Acetone
  • Methylated Spirit
  • Abrasive cleaners
  • Aggressive solvents such as Toluene.
Fire Properties

The major building codes in the USA recommend NFPA 286, Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth, for testing thermoplastics to be used as interior finishes.

This full-scale test is considered appropriate for determining the hazard of an interior finish (compared to the older ASTM E84 test methods), especially for certain plastics that can drip or melt and fall to the floor.

Lustrolite 100 complies with NFPA 286 requirements for interior finishes, however it is a combustible thermoplastic so appropriate fire precautions should always be observed.

Properties Test Method (DOT) Requirements Result
Flame spread NFPA 286 – 2015 edition (2016) Must not spread to the ceiling or the outer extremities Meets criteria
Flashover NFPA 286 – 2015 edition (2016) Must not occur Meets criteria
Peak Heat release NFPA 286 – 2015 edition (2016) Must be below 1,000sqm Meets criteria
Smoke released NFPA 286 – 2015 edition (2016) Must be below 1,000sqm Meets criteria
Flame spread rating CAN/UL S102.2-10 (2018) Class A = 0-25, Class B = 26-75 Class C = 76-200 25 (meets class A)
Smoke developed classification CAN/UL S102.2-10 (2018) Class A, B and C = < 450 370 (meets class A)
Burning behavior UL94 (2008) V-0**

References to the product's performance under the testing standards above are informational only. Please consult qualified building professionals to ensure that the material is suitable and compliant for the chosen application as per local building code requirements.

** Refer to manufacturer data, Lustrolite 100 characteristics are taken from the CAMPUS plastics data bank and are based on the international catalogue of basic data for plastics according to ISO 10350.